microarray spotter (versarray chip writer pro system (Bio-Rad)
Structured Review

Microarray Spotter (Versarray Chip Writer Pro System, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microarray spotter (versarray chip writer pro system/product/Bio-Rad
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "Development and Optimization of a Thrombin Sandwich Aptamer Microarray"
Article Title: Development and Optimization of a Thrombin Sandwich Aptamer Microarray
Journal: Microarrays
doi: 10.3390/microarrays1020095
Figure Legend Snippet: Specificity of aptasensor for thrombin. Fluorescence signal (635 nm) recorded on thrombin aptamer microarray after the incubation of the different indicated proteins with TBA2-Cy5 (protein and TBA2 final concentration: 500 nM and 1 mM, respectively); ( a ) thrombin, blank (TBA2-Cy5 only), BSA, lysozyme and VEGF and ( b ) corresponding microarray images.
Techniques Used: Fluorescence, Microarray, Incubation, Concentration Assay
Figure Legend Snippet: Effect of incubation time. Fluorescence signal (635 nm) recorded on TBA1 microarray ( a ) after the incubation of thrombin and TBA2-Cy5 for different times (180–120–90–60–30–15–5 min) and ( b ) corresponding microarray images.
Techniques Used: Incubation, Fluorescence, Microarray
Figure Legend Snippet: Effect of serum. Fluorescence signal (635 nm) recorded on TBA1 microarray ( a ) after the incubation of thrombin and TBA2-Cy5 complexes in presence of different Fetal Bovine Serum (FBS) dilutions (0%–10%–20%–30%–40%–50%–65%) and ( b ) corresponding microarray images.
Techniques Used: Fluorescence, Microarray, Incubation
Figure Legend Snippet: Direct and indirect method for thrombin detection. ( a ) Fluorescence signal (635 or 532 nm) plot of thrombin aptamer microarray after the incubation of thrombin and TBA2-Cy5 (direct method, red squares, 635 nm) or thrombin and TBA2-biotin plus Cy3-streptavidin (indirect method, green dots, 532 nm) and ( b ) relative microarray images. Tested thrombin dilutions were: 200 nM–100 nM–50 nM–10 nM–5 nM–1 nM–0 nM. TBA2-Cy5 (red squares) or TBA2-biotin (green dots) concentration was 400 nM. For the indirect method the microarray slide was incubated for 1 h with Cy3-streptavidin, for a total incubation time of two hours in all cases.
Techniques Used: Fluorescence, Microarray, Incubation, Concentration Assay
Figure Legend Snippet: Thrombin calibration curves in FBS solution. ( a ) fluorescence signal (532 nm) plot of TBA1 microarray in 20% FBS solution after the incubation of thrombin and TBA2-biotin plus Cy3-streptavidin and ( b ) corresponding microarray images. Tested thrombin dilutions were: 50 nM–10 nM–5 nM–1 nM–0.5 nM–0 nM, with a fixed TBA-2 biotin concentration of 200 nM.
Techniques Used: Fluorescence, Microarray, Incubation, Concentration Assay